Skip to content

Embed in a daemon

A host's view is go-fabric as a whole program written for the page. This page is the same pattern inside a daemon that already exists: go-zendure2mqtt, which bridges Zendure energy stores to MQTT, gains an optional Matter side. Each Zendure unit becomes one bridged endpoint, and a Matter controller shows the unit's charge level and power. The daemon's pull request SukramJ/go-zendure2mqtt#64 does it in one commit per step, and each step below links its commit.

The walkthrough was written against go-fabric v0.10.8, and its code is the daemon's at those commits. A new daemon starts from the latest release; the migration guide and the CHANGELOG name what moved since.

The daemon imports node, device, contract and the <cluster>def packages, and nothing below them. A test in the daemon holds that (TestFabricImportsOnlyTheFacade). It does the work of go-fabric's script/archcheck in one function.

1. The dependency

go get thingfabric.dev/go-fabric@latest

A daemon pins a tag, never a commit: @latest resolves to the newest release tag, and go.mod records it. go-fabric is Apache-2.0. A daemon that imports it links four of its direct dependencies — filippo.io/nistec, github.com/miekg/dns, golang.org/x/net and modernc.org/sqlite — and their indirect modules, all permissive (see THIRD-PARTY-NOTICES.md); the fifth, golang.org/x/tools, serves only the repository's own tooling. The pure-Go SQLite driver is the largest of them. A daemon with a licence gate runs it over the new graph. go-licenses does not classify modernc.org/mathutil's BSD-3-Clause LICENSE file, so the daemon ignores that one module by name, with the reason in its Makefile.

Commit: 6de3e76.

2. node.Config from the daemon's config

The daemon has its own config file, so the node's settings are a block in it. The block is off by default, so nothing changes for an installation that does not set it:

Key Default node.Config
MATTER_ENABLED false — (nothing is built)
MATTER_LISTEN :5540 Network.Listen
MATTER_STORE_PATH a file next to the config file Store.Path
MATTER_PASSCODE, MATTER_DISCRIMINATOR 20202021, 3840 Commissioning.Passcode, .Discriminator
MATTER_VENDOR_ID, MATTER_PRODUCT_ID 0xFFF1, 0x8001 (CSA test vendor) ProductDescription
MATTER_LABEL the daemon's name BasicInformation.NodeLabel

The facade generates no commissioning values: a zero passcode fails Config.Validate. The defaults are therefore the public values the reference bridge pairs with, and the daemon's README tells the operator to change the passcode before pairing for real. The PBKDF parameters (Commissioning.PBKDFIterations, .Salt) are constants of the daemon. Validation in the daemon refuses an enabled block that the node would refuse (a listen address without a port, a store path in a directory that does not exist, a trivial passcode) in the same way it refuses its other keys.

Two fields are easy to forget:

  • Logger is the daemon's own *slog.Logger. The node then logs through the daemon's handler and level, and a log-level change reaches it too (ADR 0026 principle 9).
  • BasicInformation.SoftwareVersion and .SoftwareVersionString carry the daemon's version, not go-fabric's.

node.New(ctx, cfg) builds the node and binds nothing yet; ctx bounds the store work, and none of the node's goroutines runs before Start (the opt-in Config.Client stack excepted).

Commits: 3cfa56c (the block), 6de3e76 (NodeConfig).

3. The device: one daemon entity as a typed declaration

Pick the device type in two steps. A device that measures gets the sensor device type of its measurement. A device with a battery declares PowerSource, which BridgedNode allows on every bridged device under the condition BridgedPowerSourceInfo. A Zendure unit measures AC power and carries a battery, so it is an ElectricalSensor with a PowerSource. In the typed form (since v0.10.9; the daemon's v0.10.8 form follows below) the declaration is:

dev, err := device.NewElectricalSensor(device.Options{
    StableKey: device.StringKey("zendure:" + sn), Name: name, Vendor: "Zendure", DeviceAddress: sn,
},
    powertopologydef.Declare{Features: powertopologydef.FeatureNodeTopology},
    electricalpowermeasurementdef.Declare{Features: electricalpowermeasurementdef.FeatureAlternatingCurrent,
        Initial: electricalpowermeasurementdef.Patch{PowerMode: …, NumberOfMeasurementTypes: …, Accuracy: …}},
    powersourcedef.Declare{Features: powersourcedef.FeatureBattery,
        Initial: powersourcedef.Patch{Order: new(uint8(0)), BatReplacementNeeded: new(false), …}},
)
  • PowerTopology is mandatory, and the kit applies no feature selection to it. An empty declaration is refused because PowerTopology needs one of NodeTopology, TreeTopology and SetTopology. NodeTopology, which says the measurement applies to the endpoint itself, is the smallest choice that conforms.
  • ElectricalPowerMeasurement needs AC or DC, and the host states its Accuracy (an entry for ActivePower and one for every other measurement type it serves) and its NumberOfMeasurementTypes. matter.js has no defaults for either.
  • PowerSource's EndpointList names the device's own endpoint. The kit fills it, together with Status, Description and BatChargeLevel. The host states Order and BatReplacementNeeded.
  • The declared PowerSource states BridgedPowerSourceInfo for the bridged node, under which BridgedNode makes PowerSourceConfiguration mandatory (its conformance BridgedPowerSourceInfo, D only announces a deprecation). The kit mounts it with its default server, so the device reports no device-type violation; powersourceconfigurationdef.Declare states its Sources when the host wants them listed.

The stable key is the unit's serial number, the identity the daemon already uses for its MQTT topics. Under it the unit keeps its endpoint number across restarts.

v0.10.8 and the battery. powersourcedef.Declare on an ElectricalSensor needs v0.10.9, which carries this cookbook's facade fix (CHANGELOG 0.10.9, Added). At v0.10.8 the kit refuses the declaration because the type does not list the cluster. The daemon therefore takes the route v0.10.8 has for a battery beside a measurement: device.Measurement(src) with a source of class contract.MeasurementBattery. The kit serves that source as the device's PowerSource, with BatPercentRemaining from the percentage. At v0.10.8 that battery's changes reach a subscriber only through device.WithChangeNotifier(src); the second fix of this page's pull request (CHANGELOG 0.10.9, Fixed) makes the kit's server forward them itself. v0.10.9 carries both fixes, so a daemon on it or later uses the typed declaration.

Commit: 0bac952 (internal/fabric/projection.go newUnit, internal/fabric/battery.go).

4. The aggregator batch at the device run

The batch is the one from newNode in A host's view: Aggregator().Add for each device. A daemon has to decide when a device is added and when it is gone:

  • At start the daemon adds every device its backend lists (Source.Devices()) before Start, so the first reading finds its endpoint in place.
  • A device that appears later goes through the same Add, on a running node, which then reassembles. A cloud login can list a unit after the start, and a reading can name a unit the node does not serve yet.
  • A slow login renumbers nothing: the stored endpoint number of a unit not yet listed is kept however long the list takes, since the node never drops a number because its device is absent (v0.13.0 removed MarkComplete, the call that let it).
  • A device that vanishes: the daemon never removes a unit (its state and its MQTT side keep every serial it saw), and the projection mirrors that. A unit the backend no longer reaches becomes unreachable (step 6). Aggregator().Remove is for a host that does drop a device.

Commit: 0bac952 (addKnown, ensure, markComplete).

5. Readings to attributes

The daemon's readings already go through one fan-out, the coordinator, which publishes them to MQTT. The node is attached there as one more consumer, next to Home Assistant discovery, and does not get a second reading path. Each reading becomes a Set on the typed server, with only the attributes that changed:

mw := int64(math.Round((gridInput - homeOutput) * 1000)) // positive imported
err := dev.ElectricalPowerMeasurement().Set(electricalpowermeasurementdef.Patch{ActivePower: &mw})

ActivePower is in milliwatts, and its sign follows the cluster: positive for power imported, negative for power exported (matter.js electrical-power-measurement.resource.ts:160-163 at db021da0). The battery level is a percentage, and PowerSource serves it as BatPercentRemaining in half-percent (80 % is 160). The kit stores each Set, advances the cluster's data version and reports the change to every subscribed controller, so the daemon does no reporting of its own.

Commit: 3c05e46 (internal/fabric/readings.go).

6. Lifecycle and reachability

  • Start before the backend runs, stop after it. The node starts after the daemon's MQTT link and before the coordinator drives the backend. It stops on shutdown after the backend has stopped and before the MQTT link closes. With MATTER_ENABLED set, a failing node.New or Start is a startup error of the daemon. It never falls back silently to a daemon without its Matter side.
  • SetReachable follows the backend's own word. Each DeviceReachable(dev, ok) of the daemon's observer becomes dev.SetReachable(ctx, ok), which sets BridgedDeviceBasicInformation Reachable and emits its ReachableChanged event. SetReachable is idempotent, so the backend's repeated calls cost nothing.
  • Upstream down. While the backend's upstream is unusable (the cloud session dropped, or no local unit answers) every unit is unreachable. When the upstream is back, each unit returns to its own reachability.

The coordinator remains the backend's only observer and hands every reading and observer call to an optional Projection. With the block off that projection is nil, and the MQTT side runs exactly as before.

Commit: c687e7e.

7. The pairing code into the UI and MQTT

Node.SetupPayload() returns the QR payload and the manual code for the configured passcode and discriminator, before and after Start. The daemon puts them in three places:

  • one info log line at start (zendure2mqtt.matter_pairing);
  • the retained <name>/info, where the daemon already publishes its build and connection;
  • the diagnostic web UI's status line, served from /api/health.

A Home Assistant entity for the code was left out: the code pairs only while the commissioning window is open, and the window is open until the first controller has paired or for 48 hours, and again at each start while the node is unpaired.

Commit: f603c28.

8. Running it

The daemon's packaging decides how it runs: its Dockerfile, its Home Assistant add-on, a service unit. go-fabric ships none of these. What the node needs from that packaging:

  • the store file on persistent storage, since losing it unpairs the bridge;
  • UDP 5540 and mDNS on the controllers' LAN, which in a container means host networking;
  • IPv6 on that LAN.

The operations page lists all of it from the node's side: files, ports, logs, health, limits, reset and upgrade. The daemon's README section "Matter controllers" is the operator's version.

Commit: 1d552bf.

What you did not have to do

The import test forbids every package below the facade, and the daemon needed none of them:

  • no cluster ids, attribute ids or TLV: the typed Declare, Patch and Set of each <cluster>def package;
  • no bridge, endpoint or im: the Aggregator assembles the endpoints, their Descriptor and BridgedDeviceBasicInformation, and the subscription engine reports what Set stored;
  • no mdns: the node advertises itself, with the discriminator subtype that Apple Home and Google Home browse for;
  • no secure, transport or session code: PASE, CASE, MRP and the commissioning window are the node's own;
  • no store: Store.Path is one SQLite file that the node opens and closes.

What a controller sees

The daemon's tests commission the node with go-fabric's in-process controller (fabrictest). They read what Apple Home or Home Assistant would read from the same node:

  • one endpoint per unit under the Aggregator, whose Descriptor lists ElectricalSensor and BridgedNode and serves PowerTopology, ElectricalPowerMeasurement and PowerSource;
  • NodeLabel as Home Assistant names the unit, and Reachable;
  • after a reading, BatPercentRemaining 160 for 80 % and ActivePower −600000 for 600 W fed to the home;
  • a second reading arriving through a subscription, as it would to a controller;
  • Reachable false after DeviceReachable(false), again through the subscription.

A controller shows this as a battery level and a power reading on one accessory. The bridge carries the CSA test vendor and go-fabric's test attestation chain, so a controller may warn that it is uncertified. The proof that this works is the daemon pull request's tests together with a real pairing against a unit on the LAN. That pairing is the owner's manual step, and this page does not claim it.

Source: the daemon pull request SukramJ/go-zendure2mqtt#64; node/config.go (Config, Commissioning, Store), node/aggregator.go (Add), device/electrical_sensor_gen.go, device/base.go (withBridgedPowerSource, Device.PowerSource), device/lifecycle.go (SetReachable), node/inspect.go (SetupPayload).