Thermostat¶
The kit's Thermostat server (cluster/thermo, cluster 0x0201) is a
semantic port of matter.js's ThermostatServer. A device declares it with
thermostatdef.Declare (or builds it with thermo.New), and the host
reaches it through the Sink and a set of inbound setters. The week
programs (MatterScheduleConfiguration) add a second port, the
SchedulePort.
Features¶
| Feature | Served | Note |
|---|---|---|
| Heating (HEAT), Cooling (COOL) | yes | at least one; the device type's choice |
| AutoMode (AUTO) | yes | needs HEAT and COOL, cleared otherwise |
| LocalTemperatureNotExposed (LTNE) | yes | |
| Occupancy (OCC) | yes | the host reports occupancy with SetOccupied |
| Presets (PRES) | yes | presets and the atomic write, persisted through a PresetStore |
| MatterScheduleConfiguration (MSCH) | yes | matter.js's, behind its forward feature; here behind the extension BD-chip-Thermostat-Schedules; see Week programs |
| ScheduleConfiguration, Setback | no | deprecated; matter.js refuses them |
| Events (TEVT) | yes | ahead of matter.js, after connectedhomeip; see Events |
| ThermostatSuggestions | no |
thermo.New refuses a selection naming a feature it does not serve
(thermo.ErrFeatures).
Optional attributes on request¶
| Attribute | Served when | Controller write | Device change |
|---|---|---|---|
TemperatureSetpointHold (0x0023) |
ThermostatConfig.TemperatureSetpointHold is set, or the declaration's Initial sets it |
reaches Sink.SetTemperatureSetpointHold before it is stored |
SetTemperatureSetpointHold |
TemperatureSetpointHoldDuration (0x0024) |
with the hold; starts null | stored as written (null, or up to 1440 minutes); no Sink, no hold timer | the typed server's Set |
ThermostatRunningState (0x0029) |
ThermostatConfig.ThermostatRunningState is set, or the declaration's Initial sets it |
read-only | SetThermostatRunningState |
The hold says whether the device follows its program
(SetpointHoldOff, 0) or holds the setpoint it has (SetpointHoldOn, 1).
The running state is a RelayStateBitmap: the relays the device runs
right now (Heat, Cool, Fan and their second and third stages).
SetpointHoldExpiryTimestamp is not served, and the server keeps no hold
timer: matter.js leaves both to the implementer. The hold reaching the host
is this module's addition. matter.js stores the hold and does not react to
it.
Week programs (MSCH)¶
matter.js implements MatterScheduleConfiguration behind its forward
feature thermostat-msch (ThermostatServer.ts:267-271 at b25ed960).
This server mirrors it — the write rules, the normalisation, the commit
checks and the ScheduleTypes start checks — and serves it behind the
extension BD-chip-Thermostat-Schedules, off by default
(surface.Policies.Extensions; the reference bridge's
--thermostat-schedules).
Configuration. ThermostatConfig, or the declaration's Initial
under the attribute names, holds:
ScheduleTypes: one to three types, each a SystemMode with its number of schedules and its features (presets, setpoints, names, Off). They may name only Auto, Heat or Cool, none twice, each supporting presets or setpoints (thermo.ErrSchedules).NumberOfSchedules,NumberOfScheduleTransitionsandNumberOfScheduleTransitionPerDay. A nil per-day count means no limit.Schedules: the device's own week programs, held to the content rules a controller's write is held to. A null handle gets a generated one. A nullBuiltIntakes the stored schedule's value for that handle, else false: setBuiltIn: trueon a program a controller may not remove.ActiveScheduleHandle: the schedule the device follows now.
The types and counts are configuration. The typed Set refuses them.
SchedulePort. The port is set through Declare.SchedulePort or
ThermostatConfig.SchedulePort.
| Method | Called for |
|---|---|
SetActiveSchedule(ctx, handle) |
a SetActiveScheduleRequest whose handle names a stored schedule. The server answers an unknown handle INVALID_COMMAND without calling the port. |
CommitSchedules(ctx, schedules) |
the Schedules list a controller committed in an atomic write. The list is validated, and every new schedule already has a 16-byte handle the server issued. |
An error refuses the change, as for the Sink. Without a port the server
keeps the schedules in memory. The device's own changes come back through
SetSchedules and SetActiveScheduleHandle, or through the typed Set.
These calls do not use the port. SetSchedules is the host's
authoritative replace: it is held to the content rules (types and counts,
names, presets, transitions, limits, deadband, unique handles) but not to
the lifecycle rules of a controller's write — a new handle, a changed or
dropped built-in schedule and a dropped active schedule are accepted, and
a dropped active schedule clears the active handle
(BD-Thermostat-HostSchedules). Its errors are IM statuses.
The write. A controller writes Schedules only inside an
AtomicRequest BeginWrite … CommitWrite.
- Any other write answers INVALID_IN_STATE. A write from another peer during an atomic write also answers INVALID_IN_STATE; Presets answers that case BUSY.
- BeginWrite stages nothing: until its first write the holder reads the stored list.
- Each write is validated with matter.js's write rules: the handle rules (a handle the device never issued is NOT_FOUND, a new schedule is not built in, BuiltIn does not change), the schedule type, the transitions per schedule, names and presets only where the type supports them, the transition rules (a SystemMode other than the schedule's, the setpoints within the limits and the deadband, the presets among the writing peer's pending or the stored ones), then the count limits.
- The peer that holds the write reads its pending list.
- CommitWrite validates the staged Schedules again against the Presets of the same atomic write. A built-in schedule the list drops is CONSTRAINT_ERROR, and an active schedule it drops is INVALID_IN_STATE.
- A Presets commit, or a local
SetPresets, that drops a preset a schedule names is INVALID_IN_STATE. - Only when every check passes does the commit hand the list to the port.
With the Events feature (TEVT), SetActiveScheduleRequest emits
ActiveScheduleChange with the previous and the new handle.
Events (TEVT)¶
The server follows matter.js, which emits all eight events behind its
forward feature thermostat-events (ThermostatServer.ts:2082-2259 at
b25ed960): every event needs TEVT, and the EventList carries the events
of the selection (LocalTemperatureChange without LTNE, OccupancyChange
with OCC, RunningModeChange with AUTO, ActiveScheduleChange with MSCH,
ActivePresetChange with PRES). An event goes out after its change
committed, and none for a value that did not change. Unlike matter.js,
where the application enables each event, TEVT selects every event its
conformance admits (notes/parity/by_design.md, the events paragraph of
BD-chip-Thermostat-Schedules).
| Event | Emitted when | Payload |
|---|---|---|
| SystemModeChange | SystemMode changes (a write, SetSystemMode, SetAttributes) |
the previous and the current mode |
| LocalTemperatureChange | LocalTemperature moves by at least the threshold, or between null and a value (SetLocalTemperature, SetAttributes); at most one per 60 s, a change held back is re-decided when the 60 s end |
the current value, null included |
| SetpointChange | one of the four occupied and unoccupied setpoints changes, by a write, a command, a host setter, a companion the deadband moves or the start's reconcile | Heat or Cool, the previous and the current setpoint, and Occupied or no occupancy only with OCC; a user limit emits none |
| RunningStateChange | ThermostatRunningState changes | the previous and the current relays |
| RunningModeChange | ThermostatRunningMode changes (SetThermostatRunningMode) |
the previous and the current mode |
| ActiveScheduleChange | the active schedule handle changes, from any source: SetActiveScheduleRequest, SetActiveScheduleHandle, a SetSchedules that drops the active schedule, the start clearing a handle that names no schedule |
the previous and the new handle |
| ActivePresetChange | the active preset handle changes, from any source: SetActivePresetRequest, SetActivePresetHandle, ActivatePreset, a write of a setpoint in effect — or of a setpoint limit whose reconcile moves that setpoint — that ends the preset, the start's reconcile moving a setpoint in effect, the start clearing a stale handle |
the previous and the new handle |
| OccupancyChange | Occupied changes (SetOccupied, SetAttributes) |
the previous and the current occupancy |
The LocalTemperatureChange threshold is
ThermostatConfig.LocalTemperatureChangeThreshold (0.01 °C, 50 when nil,
as matter.js) and can be moved later with
ThermostatServer.SetLocalTemperatureChangeThreshold; with the event, 0 or
below is refused. The events of the start — a stale handle cleared, the
setpoints the initial reconcile moved — go out when the bridge first stamps
the endpoint (SetEndpoint), and a LocalTemperature set before that is the
configured value, which emits nothing.
With TEVT and AUTO the server serves ThermostatRunningMode (0x001E),
which the selection makes mandatory. The host sets it with
SetThermostatRunningMode: Off always, Cool with COOL, Heat with HEAT,
anything else ConstraintError, as chip's SetRunningMode does. The
events of a host change go to the endpoint the bridge stamped
(SetEndpoint); a command's go to its endpoint.
Ecosystems. Hosts gate MSCH behind a flag, off by default, until a live pairing is verified. From issue #273, verbatim:
No source found that Apple Home, Google Home or Alexa render MSCH or
TemperatureSetpointHold. Apple once aborted pairing on an endpoint that announced an unknown cluster (the draft Schedules cluster 0x0024; the reference host recorded it). MSCH is a feature bit of the known Thermostat cluster, but whether Apple tolerates the bit is unverified — a live pairing test before any host enables it.
The reference bridge serves MSCH only with --thermostat-schedules.
The Sink¶
Declare.Sink (thermo.ThermostatConfig.Sink) is told about every change
a controller asks for, after the server validated it and before anything
is stored:
| Method | Called for |
|---|---|
SetSystemMode(ctx, mode) |
a SystemMode write |
SetSetpoint(ctx, attrID, value, companions) |
an occupied or unoccupied setpoint write, a SetpointRaiseLower, the setpoints a SetActivePresetRequest moves |
SetTemperatureSetpointHold(ctx, hold) |
a TemperatureSetpointHold write, when the hold is served |
An error refuses the change. The write or command answers with the
error's status when it carries one (a contract.StatusError or an
im.StatusCodeError), and with
FAILURE otherwise. Nothing is stored. A value equal to the stored one is
no change: the server answers SUCCESS without calling the Sink. Without a
Sink the server stores every change itself.
Inbound setters¶
The device's own changes come back through SetLocalTemperature,
SetSystemMode, SetOccupiedHeatingSetpoint, SetOccupiedCoolingSetpoint,
SetOccupied, SetAbsoluteSetpointLimit, SetPresets,
SetActivePresetHandle, SetTemperatureSetpointHold and
SetThermostatRunningState, the kit server's methods. The typed server's
Set reaches every one of them (a Patch with Presets goes through
SetPresets, one with ActivePresetHandle sets the handle alone).
Activating a preset with its setpoints, as the SetActivePresetRequest
command does, is thermostatdef.Host's ActivatePreset
(d.Thermostat().Host().ActivatePreset(ctx, handle)): an unknown handle is
INVALID_COMMAND, nil clears the handle and moves no setpoint, and the moved
setpoints reach the Sink before they are stored. Host also carries
SetMeasuredTemperature and SetOccupied. The setters do not call the
Sink. A change they store is reported as the host's change
(contract.OriginHostSet); LocalTemperature is reported by the
subscription's own reporting instead. SetSystemMode, the setpoint setters
and the hold and running-state setters log and ignore a value the
selection cannot serve (a setpoint outside its limits is clamped);
SetAbsoluteSetpointLimit, SetPresets, SetActivePresetHandle and Set
return the refusal.
Source: cluster/thermo/schedules.go, cluster/thermo/schedules_write.go
(MSCH), cluster/thermo/atomic.go (commitWrite, precommitAtomic);
cluster/thermo/thermostat_server.go (the ThermostatFeature…
constants, ThermostatConfig, Sink, servedOptional, the inbound
Set… methods, writeHold); cluster/thermo/thermostat_typed.go
(SetAttributes); cluster/thermo/presets.go (SetPresets,